Duralyst DO-17T
Description
Duralyst DO-17T is a specially designed CuO/ZnO composite adsorbent, optimized for CO removal from propylene or other gases.
Duralyst DO-17T can be regenerated with Nitrogen and trace O2. It is typically supplied and partial reduced state.
Application
Duralyst DO-17T is engineered to effectively remove CO from propylene to very low level.
The adsorbent can also remove traces of acetylene, arsine, phosphine or sulfur (H2S, COS or mercaptans) if present in the ethylene feed.
Typical Properties
Properties |
UOM |
Specifications |
Nominal Size |
mm |
5*5 |
Shape |
|
Tablet |
Bulk Density |
g/cm³ |
1.1-1.2 |
Surface Area |
㎡/g |
>50 |
Crush Strength |
N |
>50 |
Moisture |
%wt |
<5 |
Shelf lifetime |
Year |
>5 |
Operating Temperature |
°C |
Ambient to 230 |
Packaging
200 kg/steel drum
Attention
When using this product, the information and advice given in our Safety Data Sheet should be observed.